Output channel connections
The output connection includes 4 configurable output channels. Output channels can be configured as either a Toggle switch (On/Off) or a Pulse (Momentary on). The output channels are intended to be connected to devices via an appropriate relay.
Output channelsFor details on configuring the output channels refer to: Configuring output channels
It is NOT intended that devices are connected directly to the output channels.
It is recommended that you use a relay with a built in protection diode.
The router’s output channels do NOT supply voltage to devices. The output channel’s terminals (N/O and COM) are shorted together using internal relays within the router to complete a circuit.
The output channels voltage characteristics are as follows:
Maximum throughput per channel is 200 mA.
Voltage protection up to 32 V dc (in case of inadvertent connections).
Each output channel has a 200 mA internal thermal fuse.
The router’s output channels (Channels 5 to 8) can be used to power on connected devices or systems. Output channels can be configured so that connected devices switch on automatically when the router is woken from low power mode. For further details refer to: Power management page