Circuit breaker and fuse ratings
All power connections between the VCM100 and its power source must be protected by a thermal circuit breaker or fuse, fitted close to the power connection. The connection from the output of the VCM100 to the digital Radar does not require a fuse or circuit breaker.
If you do not have a thermal circuit breaker or fuse in your power circuit (fitted to the DC distribution panel, for example), you MUST fit an in-line breaker or fuse to the positive wire of the power cable.
The following table provides suitable ratings for battery isolator switches, circuit breakers, and fuses.
Power supply |
Protection |
4kW scanner |
12kW scanner |
---|---|---|---|
12 V |
Isolator switch |
30 A (minimum rating) |
30 A (minimum rating) |
Thermal breaker |
15 A |
15 A |
|
Fuse |
20 A |
20 A |
|
24 V |
Isolator switch |
15 A (minimum rating) |
15 A (minimum rating) |
Thermal breaker |
8 A |
8 A |
|
Fuse |
10 A |
10 A |