Calibration points can be manually added to the
Calibration table. The amount of Calibration points that can be stored
is determined by the type of speed transducer and method of connection.
CalibrationSpeedSpeed calibrationAdding calibration pointsFrom the Transducer set up menu:
- Select the device that the transducer you are calibrating
is connected to.
A list of available transducer data is displayed.
- (1)Select Speed.
This step is only applicable when calibrating a speed transducer
connected via an iTC-5.
- Select Speed Calibration.
- Select Advanced.
- Select Adjust Calibration.
- Select Start.
The current Calibration table is displayed.
- Select the relevant Calibration point from the table.
- Select Options.
- Select Add cal point.
- Use the Up and Down buttons to adjust the displayed Log speed to match current SOG if
available or to match your estimated actual speed.
- Select Add.
- Select OK.
- Repeat steps 7 to 11 for each Calibration point you want
to add.
The more Calibration points you add the higher the accuracy
of Log speed will be.
Note If the text appears red then the new reading deviates
too far from the stored reading. You will need to add a Calibration
point closer to the stored reading a try again.