Alert notifications page
Alert notifications can be configured for the router’s supply voltage and input channel voltage.
Each input channel warning must be configured with a unique Alert ID with a value between 1,000 and 65,000.
Low voltage warning
A low voltage warning can be set which triggers when the voltage available to the router drops below a specified value.
By selecting Edit for a specific Low voltage warning, you can specify a unique Alert ID. You can also enable and disable notifications using the Allow notification checkbox, and specify the voltage at which the alert will be triggered.
Input channel alerts
Alerts can also be set for each input channel (Channels 1 to 4).
By selecting Edit for a specific input channel, you can specify a unique Alert ID. You can also enable and disable notifications using the Allow notification checkbox.
When the input channel’s input type has been configured as Digital voltage detect, normally open or Digital voltage detect, normally closed, you can enter a voltage and select whether the alert is triggered when the channel has Met or Not met the specified voltage. You can also enter an alert notification message.
When the input channel’s input type has been configured as Analog voltage detect, you can enter a voltage and select whether the alert is triggered when the channel’s voltage value is below or above the specified voltage. You can also enter an alert notification message.
Alert sending
When SMS and/or PUSH notifications are enabled, alerts are sent as they are triggered. However, once triggered, alerts are subject to a 10 minute “cool-down” period before the same device can send another alert. After the 10 minute cool-down period has elapsed, alerts from that device can be sent again.
SMS alerts require a cellular (mobile) number to be configured in the Boat alerts menu of the Raymarine app.