Thermal breaker / inline fuse rating
It is recommended that a thermal circuit breaker is fitted to the positive power supply cable. Alternatively a suitably-rated inline fuse can be used.
Power supply
Thermal circuit breakerPower supplyThe rating for the thermal circuit breaker / fuse should be based on the total current draw of your system.
The Master system and Remote systems are each capable of drawing up to a maximum of 100A.
Module
Module fuseEach output channel should be fused with a fuse rated appropriately for the current draw of that channel.
Each output module is supplied with the maximum rated fuse for the channel (e.g.: The High power module is supplied with a 25A fuse fitted to each channel). Ensure that if required, the fuses are changed to reflect the actual current draw of the devices connected to each channel.