Maximum IP network configuration
The recommended maximum number of supported devices on any single Ethernet / RayNet network is shown below. Whilst it may be possible to connect more products than the quantities stated, or to substitute products, exceeding the stated limits may cause the network to become unstable and networked devices to respond slower than expected.
Up to 10 x Axiom-Series / Axiom 2-Series displays.
Up to 10 x Alpha-Series displays.
Up to 8 x Simultaneous IP camera feeds (More than 8 cameras can be connected but only up to 8 can be displayed at the same time).
Up to 2 x Radar scanners (Only one can be a Quantum-Series).
Up to 4 external sonar modules.
1 x YachtSense DCS
1 x DockSense or NeuBoat Dock system.
1 x RMK-9 or RMK-10.
1 x YachtSense Link router.
Up to 3 x third-party integrated hardware devices (e.g.: Lumishore™).
It is recommended that all network devices are connected directly to an Ethernet / RayNet network switch. To ensure adequate network traffic bandwidth on larger systems involving a high volume of data throughput, a Gigabit-speed network switch is recommended (such as the RNS-5 or RNS-8).