Card reader location requirements
When selecting a location for the external card reader it is important to consider a number of factors.
Location requirementsGeneralFactors for consideration:
Mounting surface — Ensure product is adequately supported on a secure surface. Do not mount units or cut holes in places which may damage the structure of the vessel.
Cabling — Ensure the product is mounted in a location which allows proper routing, support and connection of cables:
The product should be located close to the display to which it is connected, ensuring that the cable is not stretched or pulled tight.
Minimum bend radius of 100 mm (3.94 in) unless otherwise stated.
Use cable clips to prevent stress on connectors.
If your installation requires multiple ferrites to be added to a cable then additional cable clips should be used to ensure the extra weight of the cable is supported.
Water ingress — The product should be located it in a protected area away from prolonged and direct exposure to rain and salt spray.
Electrical interference — Select a location that is far enough away from devices that may cause interference, such as motors, generators and radio transmitters / receivers.