Performing a power-on reset on an Axiom 2 Pro display

Factory resetRecovery mode
Important

Before performing a power on reset, ensure that you have backed up your settings and user data to a memory card.

  1. Switch off power at the breaker to ensure that the display is completely powered off, and not in Standby mode. Alternatively, remove the power cable from the display.
  2. Plug the power cable back in, or switch the breaker back on.
  3. If the display was previously in Standby, press the power button to power up the display, otherwise the display will power up when the power supply is re-connected.
  4. Within approximately 10 seconds of powering on your display, press and hold the Back and Menu buttons until the screen goes black and the Raymarine logo appears.
    The display will re-start into Recovery mode.
  5. Use the directional controls to highlight Wipe data / factory reset.
  6. Press Ok.
  7. Use the directional controls to highlight Factory data reset.
  8. Press Ok.
  9. When ‘Data wipe complete’ is displayed, select Reboot system now.
  10. Press Ok.