Making connections

Follow the steps below to connect the transducer cable to a RealVision™ Max 3Dsonar-capable device (i.e.: Axiom™ 2 Pro MFD or RVM1600 sonar module).
  1. Ensure that the vessel's power supply is switched off.
  2. Connect cables as follows:
    1. Connect the cable from each transducer to the Y-cable tails (A80478); check the colored labels on the cables to ensure that the transducers are connected to the correct Y-cable tail.
    2. Connect an extension cable to the remaining free plug on the Y-cable. See RealVision transducer extension cables.
  3. Ensuring correct orientation, push the transducer cable (or extension cable) connector fully onto the corresponding connector on your MFD or sonar module.
  4. Turn the locking collar clockwise to secure the cable.