Element technical specification

Table 1. Power
Element™ 7 Element™ 9 Element™ 12

Nominal supply voltage:

12 V dc

Operating voltage range:

8 V dc to 16 V dc (protected up to 32 V dc)

Fuse requirements:

  • Inline fuse = 5 Amp, or

  • Thermal breaker = 3 Amp

Power consumption:

(Approximate @ 12 V dc)

  • 7 HV — 16.8 Watts

  • 7 S — 13.2 Watts

  • 9 HV — 18 Watts

  • 9 S — 14.4 Watts

  • 12 HV — 24 Watts

  • 12 S — 19.2 Watts

Note

Power consumption figures were taken at full brightness with a transducer connected and pinging.

Table 2. Environmental
Element™ 7 Element™ 9 Element™ 12

Operating temperature range:

-25°C (-13°F) to +55°C (+131°F)

Storage temperature range:

-30°C (-22°F) to +70°C (+158°F)

Humidity:

up to 93% @ 40°C (+104°F)

Water ingress protection:

IPx6 and IPx7

Weight (display only):

1.0 Kg

1.3 Kg

2.0 Kg

Table 3. LCD specification
Element™ 7 Element™ 9 Element™ 12

Size (diagonal):

7.0”

9.0”

12.1”

Type

TN (Twisted Nematic)

IPS (In-Plane Switching)

Color depth:

24 bit

Resolution:

WVGA 800 x 480

WXGA 1280 x 800

Ratio

5:3

8:5

Maximum Illumination:

1500 nits / 1500 cd/m2

Viewing angle (T / B / L / R):

50° / 60° / 70° / 70°

50° / 70° / 70° / 70°

89° / 89° / 89° / 89°

Table 4. Data connections
Element™ 7 Element™ 9 Element™ 12

Transducer:

1 x 15–pin HyperVision™ connector.

SeaTalkng® / NMEA 2000

1 x DeviceNet female connector built into power cable

2.4 GHz Wi-Fi:

1 x 802.11/b/g/n

NMEA 2000 LEN (Load Equivalency Number):

1 (Based on 9 V dc nominal voltage)

Table 5. Storage
Element™ 7 Element™ 9 Element™ 12

External:

1 x MicroSDXC card slot