VCM100 location requirements
When selecting a mounting location it is important to consider a number of factors.
InstallationLocation requirementsVCM100Location requirementsVCM100
Mounting orientation — Ensure product is mounted vertically to allow for efficient heat dissipation.
Ventilation — Ensure that:
Equipment is mounted in a compartment of suitable size.
Ventilation holes are not obstructed. Allow adequate separation of equipment.
Mounting surface — Ensure equipment is adequately supported on a secure surface. Do not mount units or cut holes in places which may damage the structure of the vessel.
Cables — Ensure the unit is mounted in a location which allows proper routing and connection of cables:
Minimum bend radius of 100 mm (3.94 in) unless otherwise stated.
Use cable supports to prevent stress on connectors.
The maximum length of cable between the battery and the VCM100 should not normally exceed 6 m (19.69 ft). All power cable lengths should be kept as short as possible.
Water ingress — The VCM100 is splashproof, and suitable for mounting below decks only.
Electrical interference — Select a location that is far enough away from devices that may cause interference, such as motors, generators and radio transmitters/receivers.
Magnetic compass — Mount the VCM100 at least 1 m (3.28 ft) away from a magnetic compass.
Power supply — Select a location that is as close as possible to the vessel’s DC power source. This will help to keep cable runs to a minimum.