VCM100 location requirements

When selecting a mounting location it is important to consider a number of factors.

InstallationLocation requirementsVCM100Location requirementsVCM100

  • Mounting orientation — Ensure product is mounted vertically to allow for efficient heat dissipation.

  • Ventilation — Ensure that:

    • Equipment is mounted in a compartment of suitable size.

    • Ventilation holes are not obstructed. Allow adequate separation of equipment.

  • Mounting surface — Ensure equipment is adequately supported on a secure surface. Do not mount units or cut holes in places which may damage the structure of the vessel.

  • Cables — Ensure the unit is mounted in a location which allows proper routing and connection of cables:

    • Minimum bend radius of 100 mm (3.94 in) unless otherwise stated.

    • Use cable supports to prevent stress on connectors.

    • The maximum length of cable between the battery and the VCM100 should not normally exceed 6 m (19.69 ft). All power cable lengths should be kept as short as possible.

  • Water ingress — The VCM100 is splashproof, and suitable for mounting below decks only.

  • Electrical interference — Select a location that is far enough away from devices that may cause interference, such as motors, generators and radio transmitters/receivers.

  • Magnetic compass — Mount the VCM100 at least 1 m (3.28 ft) away from a magnetic compass.

  • Power supply — Select a location that is as close as possible to the vessel’s DC power source. This will help to keep cable runs to a minimum.